Model | HPS-CFL025 | Reference distance① | 43.9mm |
Measuring range | ±6mm | Linearity error | 4μm |
Static repeatability② | 0.34μm | Measuring angle | ±8.9° |
Spot diameter | 70μm | Optical fiber length | 5m(Standard); 3m/10m(Optional) |
IP protection | IP52 (Standard Level),IP67 (Bookable) | Environment temperature | 0~+50℃ |
Weight | 132g | Outer diameter | 25mm |
*① This is the value from the lens structure surface to the center point of the lens measurement range.
*② This value is a 3σ value, which is obtained by measuring the tungsten steel standard gauge block on the optical platform in our company's dust-free laboratory. The number of samples: 200000; integration time: 400us; light signal intensity (manually adjusted): 50%; moving average filter window size: 128.
*All technical specifications shall be subject to the latest official product datasheet.
*Hypersen Technologies reserves the right of final interpretation.